Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2006 Nov;29(11):649-55.
doi: 10.1111/j.1365-2761.2006.00759.x.

Sensitivity and specificity of current diagnostic tests for gill-associated virus in Penaeus monodon

Affiliations
Comparative Study

Sensitivity and specificity of current diagnostic tests for gill-associated virus in Penaeus monodon

J Munro et al. J Fish Dis. 2006 Nov.

Abstract

This study reports the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy between a reverse transcriptase-nested polymerase chain reaction (RT-nPCR) and an enzyme-linked immunosorbent assay (ELISA) for the detection of gill-associated virus (GAV) from a sample of 120 Penaeus monodon. Subsequently, the same comparisons were applied to the ELISA and haemagglutination (HA) assays for detection of GAV from a second 120 prawns. The optical density (OD) or dilution cut-off point had a direct influence on the tested parameters. The cut-off OD of 0.5-0.6 with the ELISA produced a sensitivity of 98% compared with RT-nPCR. However, these OD produced the lowest accuracy (85.8% and 86.7%, respectively). The OD cut off of 0.75 resulted in the highest accuracy (91.7%) and NPV (81.3%) while it had the second highest sensitivity (97%) and PPV (93.3%). However, the OD cut off of 0.9 had the highest specificity (80%). With regards to HA, the titre cut off at 8 resulted in the highest sensitivity, specificity and NPV (94%, 100% and 100%, respectively) compared with the ELISA, while the HA titre of 16 gave the highest accuracy (73%) and the second highest specificity (75%). A HA titre of 64 gave the highest PPV (81%). Using the RT-nPCR as the gold standard, the ELISA had an accuracy of 91.7% when using a cut off >0.75 as a positive result. When compared with the ELISA, the HA had an accuracy of 73% when using an HA titre cut off greater than 16 as a positive result. These results indicate that alternative tests for GAV (ELISA and HA) can be used to explore multiple questions about the disease status of P. monodon stocks in a cost-effective manner.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources