Reliability of respiratory tidal volume estimation by means of ambulatory inductive plethysmography
- PMID: 16817607
Reliability of respiratory tidal volume estimation by means of ambulatory inductive plethysmography
Abstract
Ambulatory monitoring of ventilatory parameters in everyday life, field research and clinical situations may offer new insights into respiratory functioning in health and disease. Recent technological advances that employ ambulatory inductive plethysmography could make monitoring of respiration outside the clinic and laboratory feasible. Inductive plethysmography provides a method for nonintrusive assessment of both timing (e.g. respiration rate) and volumetric parameters (e.g. tidal volume and minute ventilation), by which tidal volume is initially calibrated to direct measures of volume. Estimates of tidal volume assessed by this technique have been validated in laboratory investigations, usually examining within-individual relations to direct measures over a large range of tidal volume variation. However, the reliability of individual differences in tidal volume or other breathing parameters has not been tested under naturalistic measurement conditions using inductive plethysmography. We examined the test-retest reliability of respiration rate, tidal volume and other volumetric parameters of breathing over a period of six weeks of repeated measurements during baseline conditions and breathing exercises with 16 healthy freely moving volunteers in a Yoga course. Reliability of measurement was evaluated by calculating the average week-to-week between-subject correlation coefficients for each physiological measure. Additionally because body-mass index has been previously positively correlated to tidal volume, we also assessed this relationship as an external criterion of validity of tidal volume estimation. Regarding the latter, similar correlations to those previous studies were found (r = 0.6). Furthermore, reliability estimates were high and consistent across respiratory measures (typically r's = 0.7-0.8). These results suggest the validity of ambulatory inductive plethysmographic measurement of respiration, at least under relatively sedentary conditions. Findings also point to the stability of individual differences in respiratory parameters over consecutive weeks.
Similar articles
-
Accuracy of ventilatory measurement employing ambulatory inductive plethysmography during tasks of everyday life.Biol Psychol. 2010 Apr;84(1):121-8. doi: 10.1016/j.biopsycho.2010.02.008. Epub 2010 Feb 20. Biol Psychol. 2010. PMID: 20176075
-
Reliability and validity of the lung volume measurement made by the BOD POD body composition system.Clin Physiol Funct Imaging. 2007 Jan;27(1):42-6. doi: 10.1111/j.1475-097X.2007.00713.x. Clin Physiol Funct Imaging. 2007. PMID: 17204037
-
Measurements of ventilation in freely ranging subjects.Res Rep Health Eff Inst. 1993 May;(59):1-17; discussion 57-69. Res Rep Health Eff Inst. 1993. PMID: 8216969
-
Implementation and interpretation of respiratory sinus arrhythmia measures in psychosomatic medicine: practice against better evidence?Psychosom Med. 2006 Jul-Aug;68(4):617-27. doi: 10.1097/01.psy.0000228010.96408.ed. Psychosom Med. 2006. PMID: 16868273 Review.
-
The scoring of respiratory events in sleep: reliability and validity.J Clin Sleep Med. 2007 Mar 15;3(2):169-200. J Clin Sleep Med. 2007. PMID: 17557426 Review.
Cited by
-
Field based reliability and validity of the bioharness™ multivariable monitoring device.J Sports Sci Med. 2012 Dec 1;11(4):643-52. eCollection 2012. J Sports Sci Med. 2012. PMID: 24150074 Free PMC article.
-
Employing an Incentive Spirometer to Calibrate Tidal Volumes Estimated from a Smartphone Camera.Sensors (Basel). 2016 Mar 18;16(3):397. doi: 10.3390/s16030397. Sensors (Basel). 2016. PMID: 26999152 Free PMC article.
-
Separation of respiratory influences from the tachogram: a methodological evaluation.PLoS One. 2014 Jul 8;9(7):e101713. doi: 10.1371/journal.pone.0101713. eCollection 2014. PLoS One. 2014. PMID: 25004139 Free PMC article.
-
Bioharness(™) Multivariable Monitoring Device: Part. II: Reliability.J Sports Sci Med. 2012 Sep 1;11(3):409-17. eCollection 2012. J Sports Sci Med. 2012. PMID: 24149347 Free PMC article.
-
Tidal volume estimation using the blanket fractal dimension of the tracheal sounds acquired by smartphone.Sensors (Basel). 2015 Apr 27;15(5):9773-90. doi: 10.3390/s150509773. Sensors (Basel). 2015. PMID: 25923929 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources