Inertial cavitation dose produced in ex vivo rabbit ear arteries with Optison by 1-MHz pulsed ultrasound
- PMID: 16464673
- DOI: 10.1016/j.ultrasmedbio.2005.10.001
Inertial cavitation dose produced in ex vivo rabbit ear arteries with Optison by 1-MHz pulsed ultrasound
Abstract
Previous in vitro studies have shown that ultrasound-induced mechanical bioeffects with contrast agents present are highly correlated with inertial cavitation (IC) "dose" (Chen et al. 2003a, 2003c). The ex vivo experiments conducted here addressed the following hypotheses: 1. IC activity can be generated by insonating perfused rabbit ear blood vessel, and 2. the IC "dose" developed during insonation treatment can be reliably measured and will vary with varying acoustic parameters and Optison concentration. Ex vivo rabbit auricular arteries were perfused with Optison suspensions and then exposed to 1.1-MHz pulsed focused ultrasound. Experimental variables included peak negative acoustic pressure (0.2 MPa to 5.2 MPa), pulse-repetition frequency (5, 50 or 500 Hz), pulse length (50, 100, 500 or 1000 cycles), and Optison volume concentration (0, 0.2, 0.5 or 1%). Cavitation activity was quantified as IC dose, based on passive cavitation detection measurements. The results show that: 1. The IC pressure threshold decreases with higher concentrations of Optison, and 2. IC dose increases significantly with increasing acoustic pressure, Optison concentration, pulse length or with decreasing pulse-repetition frequency.
Similar articles
-
Intravascular inertial cavitation activity detection and quantification in vivo with Optison.Ultrasound Med Biol. 2006 Oct;32(10):1601-9. doi: 10.1016/j.ultrasmedbio.2006.07.015. Ultrasound Med Biol. 2006. PMID: 17045881
-
Correlation between inertial cavitation dose and endothelial cell damage in vivo.Ultrasound Med Biol. 2006 Oct;32(10):1611-9. doi: 10.1016/j.ultrasmedbio.2006.07.016. Ultrasound Med Biol. 2006. PMID: 17045882
-
Optical monitoring of ultrasound-induced bioeffects in glass catfish.Ultrasound Med Biol. 2004 Jan;30(1):67-74. doi: 10.1016/j.ultrasmedbio.2003.08.005. Ultrasound Med Biol. 2004. PMID: 14962610
-
Overview of experimental studies of biological effects of medical ultrasound caused by gas body activation and inertial cavitation.Prog Biophys Mol Biol. 2007 Jan-Apr;93(1-3):314-30. doi: 10.1016/j.pbiomolbio.2006.07.027. Epub 2006 Aug 22. Prog Biophys Mol Biol. 2007. PMID: 16989895 Review.
-
Ultrasound, cavitation bubbles and their interaction with cells.Adv Drug Deliv Rev. 2008 Jun 30;60(10):1103-16. doi: 10.1016/j.addr.2008.03.009. Epub 2008 Apr 8. Adv Drug Deliv Rev. 2008. PMID: 18468716 Review.
Cited by
-
Effect of Ultrasound Pulse Length on Sonoreperfusion Therapy.Ultrasound Med Biol. 2023 Jan;49(1):152-164. doi: 10.1016/j.ultrasmedbio.2022.08.009. Epub 2022 Oct 15. Ultrasound Med Biol. 2023. PMID: 36253230 Free PMC article.
-
An ex vivo study of the correlation between acoustic emission and microvascular damage.Ultrasound Med Biol. 2009 Sep;35(9):1574-86. doi: 10.1016/j.ultrasmedbio.2009.04.013. Epub 2009 Jun 27. Ultrasound Med Biol. 2009. PMID: 19560856 Free PMC article.
-
Ultrasound-Mediated Drug Delivery: Sonoporation Mechanisms, Biophysics, and Critical Factors.BME Front. 2022 Jan 29;2022:9807347. doi: 10.34133/2022/9807347. eCollection 2022. BME Front. 2022. PMID: 37850169 Free PMC article. Review.
-
Contrast Ultrasound, Sonothrombolysis and Sonoperfusion in Cardiovascular Disease: Shifting to Theragnostic Clinical Trials.JACC Cardiovasc Imaging. 2022 Feb;15(2):345-360. doi: 10.1016/j.jcmg.2021.07.028. Epub 2021 Oct 13. JACC Cardiovasc Imaging. 2022. PMID: 34656483 Free PMC article. Review.
-
The partitioning of nanoparticles to endothelium or interstitium during ultrasound-microbubble-targeted delivery depends on peak-negative pressure.J Nanopart Res. 2015 Aug;17(8):345. doi: 10.1007/s11051-015-3153-8. Epub 2015 Aug 22. J Nanopart Res. 2015. PMID: 26594129 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources