Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1992 Oct;46(1-4):175-88.
doi: 10.1016/0304-3991(92)90013-a.

Magnification mismatches between micrographs: corrective procedures and implications for structural analysis

Affiliations

Magnification mismatches between micrographs: corrective procedures and implications for structural analysis

A Aldroubi et al. Ultramicroscopy. 1992 Oct.

Abstract

Quantitative structural analysis from electron micrographs of biological macromolecules inevitably requires the synthesis of data from many parts of the same micrograph and, ultimately, from multiple micrographs. Higher resolutions require the inclusion of progressively more data, and for the particles analyzed to be consistent to within ever more stringent limits. Disparities in magnification between micrographs or even within the field of one micrograph, arising from lens hysteresis or distortions, limit the resolution of such analyses. A quantitative assessment of this effect shows that its severity depends on the size of the particle under study: for particles that are 100 nm in diameter, for example, a 2% discrepancy in magnification restricts the resolution to approximately 5 nm. In this study, we derive and describe the properties of a family of algorithms designed for cross-calibrating the magnifications of particles from different micrographs, or from widely differing parts of the same micrograph. This approach is based on the assumption that all of the particles are of identical size: thus, it is applicable primarily to cryo-electron micrographs in which native dimensions are precisely preserved. As applied to icosahedral virus capsids, this procedure is accurate to within 0.1-0.2%, provided that at least five randomly oriented particles are included in the calculation. The algorithm is stable in the presence of noise levels typical of those encountered in practice, and is readily adaptable to non-isometric particles. It may also be used to discriminate subpopulations of subtly different sizes.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms

LinkOut - more resources