Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1999 Nov;60(5):269-74.
doi: 10.1016/s0010-7824(99)00097-9.

Comparison of efficacy, cycle control, and tolerability of two low-dose oral contraceptives in a multicenter clinical study

Affiliations
Clinical Trial

Comparison of efficacy, cycle control, and tolerability of two low-dose oral contraceptives in a multicenter clinical study

J Endrikat et al. Contraception. 1999 Nov.

Abstract

This study compares the contraceptive reliability, cycle control, and tolerability of two oral contraceptive preparations containing 20 micrograms of ethinyl estradiol combined with either 75 micrograms of gestodene (EE/GSD) or 150 micrograms of desogestrel (EE/DSG). Women received the trial preparations daily for 21 days, followed by a 7-day pill-free interval. Contraceptive efficacy, cycle control, and tolerability were evaluated over a period of 12 cycles. Efficacy data of 14,700 treatment cycles (EE/GSD: 7299; EE/DSG: 7401) were obtained from 1476 women (EE/GSD, n = 740; EE/DSG, n = 736). Both preparations provided effective contraception and good cycle control with a similarly low incidence of both spotting and breakthrough bleeding. The spotting rates in both treatment groups decreased from 35.1% (EE/GSD) and 37.5% (EE/DSG) in the first treatment cycle to approximately 10% in the fourth treatment cycle. The spotting incidence as percent of the total number of cycles was 12.7% for EE/GSD and 14.3% for EE/DSG. The breakthrough bleeding incidence was 5.2% of all cycles for EE/GSD and 6.0% of all cycles for EE/DSG. For 84.7% of the cycles in the gestodene group and for 82.5% of the cycles in the desogestrel group, neither spotting nor breakthrough bleeding were recorded. Overall, the spotting and breakthrough bleeding incidence tended to be lower with EE/GSD than with EE/DSG. However, the difference was not statistically significant. Amenorrhea was recorded in 2.7% of the cycles with EE/GSD and in 2.9% with EE/DSG. Both preparations were well tolerated and showed a similar pattern of adverse events. More than 83% of the women in both groups either did not gain weight or lost more than 2 kg. Both preparations had a beneficial effect on dysmenorrhea. Both regimens provided reliable contraception and good cycle control. The incidence of adverse events was relatively low and both preparations were well tolerated.

PIP: This study compares the contraceptive reliability, cycle control, and tolerability of two oral contraceptive preparations containing 20 mcg of ethinyl estradiol combined with either 75 mcg of gestodene (EE/GSD) or 150 mcg of desogestrel (EE/DSG). Women received the trial preparations daily for 21 days, followed by a 7-day pill-free interval. Contraceptive efficacy, cycle control, and tolerability were evaluated over a period of 12 cycles. Efficacy data of 14,700 treatment cycles (EE/GSD: 7299; EE/DSG: 7401) were obtained from 1476 women (EE/GSD, n = 740; EE/DSG, n = 736). Both preparations provided effective contraception and good cycle control with a similarly low incidence of both spotting and breakthrough bleeding. The spotting rates in both treatment groups decreased from 35.1% (EE/GSD) and 37.5% (EE/DSG) in the first treatment cycle to approximately 10% in the fourth treatment cycle. The spotting incidence as percent of the total number of cycles was 12.7% for EE/GSD and 14.3% for EE/DSG. The breakthrough bleeding incidence was 5.2% of all cycles for EE/GSD and 6.0% of all cycles for EE/GSD. For 84.7% of the cycles in the gestodene group and for 82.5% of the cycles in the desogestrel group, neither spotting nor breakthrough bleeding were recorded. Overall, the spotting and breakthrough bleeding incidence tended to be lower with EE/GSD than with EE/DSG. However, the difference was not statistically significant. Amenorrhea was recorded in 2.7% of the cycles with EE/GSD and in 2.9% with EE/DSG. Both preparations were well tolerated and showed a similar pattern of adverse events. More than 83% of the women in both groups either did not gain weight or lost more than 2 kg. Both preparations had a beneficial effect on dysmenorrhea. Both regimens provided reliable contraception and good cycle control. The incidence of adverse events was relatively low and both preparations were well tolerated.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms

LinkOut - more resources