Abstract
The aim of the present study was to evaluate the possible utilization of saliva and urine as alternative samples to serum for the diagnosis of human immunodeficiency virus (HIV) infection. A total of 302 individuals participated in the study: 187 HIV-infected individuals (106 had Centers for Disease Control and Prevention [CDC] stage II infection, 19 had CDC stage III infection, and 62 had CDC stage IV infection) and 115 noninfected persons (46 of the noninfected persons were blood donors and 69 belonged to a group at high risk of HIV infection). Paired saliva and urine samples were taken from each of the participants in the study. The presence of HIV-specific antibodies was detected by an enzyme-linked fluorescent assay (ELFA), and the result was confirmed by Western blot analysis (WB). The ELFA with saliva gave maximum sensitivity and specificity values, while ELFA had lower sensitivity (95.2%) and specificity (97. 4%) values for detection of HIV antibody in urine samples. WB with all saliva samples fulfilled the World Health Organization criterion for positivity, while only 96.8% of the urine samples were confirmed to be positive by WB. Among the four reactivity patterns found by WB of these alternative samples, the most frequent included bands against three groups of HIV structural proteins (was ENV, POL, and GAG). The reactivity bands most frequently observed were those for the proteins gp160 and gp120. The least common reactivity band was the band for protein p17. The detection of HIV antibodies in saliva samples by means of ELFA with the possibility of later confirmation by WB makes saliva an alternative to serum for possible use in the diagnosis of infection. In contrast, HIV antibody detection in urine samples by the same methodology (ELFA) could be taken into consideration for use in epidemiological studies.
Figures
Similar articles
-
Urinary HIV-1 antibody patterns by western blot assay.Clin Lab Sci. 1998 Nov-Dec;11(6):336-8. Clin Lab Sci. 1998. PMID: 10345498
-
[Oral fluid and urine as alternative samples in confirmatory testing of HIV-1 infection].Rev Cubana Med Trop. 2007 May-Aug;59(2):134-8. Rev Cubana Med Trop. 2007. PMID: 23427447 Clinical Trial. Spanish.
-
More reliable diagnosis of infection with human immunodeficiency virus type 1 (HIV-1) by detection of antibody IgGs to pol and gag proteins of HIV-1 and p24 antigen of HIV-1 in urine, saliva, and/or serum with highly sensitive and specific enzyme immunoassay (immune complex transfer enzyme immunoassay): a review.J Clin Lab Anal. 1997;11(5):267-86. doi: 10.1002/(SICI)1098-2825(1997)11:5<267::AID-JCLA5>3.0.CO;2-4. J Clin Lab Anal. 1997. PMID: 9292394 Free PMC article. Review.
-
Staging of recent HIV-1 infection using Geenius rapid confirmatory assay compared to INNO-LIA, New Lav and Blot 2.2 assays.J Clin Virol. 2017 Oct;95:47-51. doi: 10.1016/j.jcv.2017.08.003. Epub 2017 Aug 18. J Clin Virol. 2017. PMID: 28843384
-
[Serology of HIV infection].Hautarzt. 1989 Dec;40(12):745-51. Hautarzt. 1989. PMID: 2695498 Review. German.
Cited by
-
Urinary immunoglobulins in viral diagnosis: An overview.Indian J Med Res. 2022 Jan;155(1):11-21. doi: 10.4103/ijmr.IJMR_808_18. Indian J Med Res. 2022. PMID: 35859424 Free PMC article. Review.
-
Human virus detection with graphene-based materials.Biosens Bioelectron. 2020 Oct 15;166:112436. doi: 10.1016/j.bios.2020.112436. Epub 2020 Jul 22. Biosens Bioelectron. 2020. PMID: 32750677 Free PMC article. Review.
-
Detection of hepatitis C virus antibodies in oral fluid specimens for prevalence studies.Eur J Clin Microbiol Infect Dis. 2008 Feb;27(2):121-6. doi: 10.1007/s10096-007-0408-z. Epub 2007 Nov 20. Eur J Clin Microbiol Infect Dis. 2008. PMID: 18027006
-
Microfluidic immunoassays as rapid saliva-based clinical diagnostics.Proc Natl Acad Sci U S A. 2007 Mar 27;104(13):5268-73. doi: 10.1073/pnas.0607254104. Epub 2007 Mar 20. Proc Natl Acad Sci U S A. 2007. PMID: 17374724 Free PMC article.
-
Evaluation of a commercial enzyme immunoassay for HIV screening in urine.Eur J Clin Microbiol Infect Dis. 2004 Nov;23(11):831-5. doi: 10.1007/s10096-004-1221-6. Epub 2004 Oct 8. Eur J Clin Microbiol Infect Dis. 2004. PMID: 15480885
References
-
- Adams L E, Donovan B R, Friedman K A, El Ramahi K, Hess E V. Sperm and seminal plasma antibodies in acquired immune deficiency (AIDS) and other associated syndromes. Clin Immunol Immunopathol. 1988;46:442–449. - PubMed
-
- Akker R, Hoek J A, Akker W M, Kooy H, Vijge E, Roosendaal G, Coutinho R A, Loon A M. Detection of HIV antibodies in saliva as a tool for epidemiological studies. AIDS. 1992;6:953–957. - PubMed
-
- Behets F M, Edidi B, Quinn T C, Atikala L, Bishagara K, Nzila N, Laga M, Piot P, Ryder R W, Brown C C. Detection of salivary HIV-1 specific IgG antibodies in high-risk populations in Zaire. J Acquired Immune Defic Syndr. 1991;4:183–187. - PubMed
-
- Belec L, Georges A J, Steenman G, Martin P M. Antibodies to human immunodeficiency virus in vaginal secretions of heterosexual women. J Infect Dis. 1989;160:385–391. - PubMed
-
- Belec L, Georges A J, Steenman G, Martin P M. Antibodies to human immunodeficiency virus in the semen of heterosexual men. J Infect Dis. 1989;159:324–327. - PubMed
MeSH terms
Substances
LinkOut - more resources
Full Text Sources