You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
EDIT (I wrote the earlier comments in wrong issue)
I updated the old notebook in PR #94 reruning it with the current code.
The old differences in photon density are gone now, everything with flux is consistent, so closing this issue
In https://github.com/jsitarek/agnpy/blob/master/tests/basic/simple_ec.ipynb I put a few tests of the EC code comparing it with back of the envelope calculations.
in [16] (test2) compares the flux of the EC spectrum for Thomson case without beaming
in [23] (test3) there is the same check done in K-N regime (still without beaming)
in [27] (test4) the same is done for Thomson regime but with strong beaming,
in all the 3 cases the obtained flux is about a factor 2 lower than what I would expect from the back on the envelope calculations
The text was updated successfully, but these errors were encountered: