This repository has been archived by the owner on Apr 17, 2024. It is now read-only.
-
Notifications
You must be signed in to change notification settings - Fork 1
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Signed-off-by: Deepika Upadhyay <deepika@koor.tech>
- Loading branch information
Deepika Upadhyay
committed
Nov 30, 2023
1 parent
e911cea
commit 1439b5a
Showing
2 changed files
with
444 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,313 @@ | ||
################################################################################################################# | ||
# Define the settings for the rook-ceph cluster with common settings for a production cluster. | ||
# All nodes with available raw devices will be used for the Ceph cluster. At least three nodes are required | ||
# in this example. See the documentation for more details on storage settings available. | ||
|
||
# For example, to create the cluster: | ||
# kubectl create -f crds.yaml -f common.yaml -f operator.yaml | ||
# kubectl create -f cluster.yaml | ||
################################################################################################################# | ||
|
||
apiVersion: ceph.rook.io/v1 | ||
kind: CephCluster | ||
metadata: | ||
name: rook-ceph | ||
namespace: rook-ceph # namespace:cluster | ||
spec: | ||
cephVersion: | ||
# The container image used to launch the Ceph daemon pods (mon, mgr, osd, mds, rgw). | ||
# v16 is Pacific, and v17 is Quincy. | ||
# RECOMMENDATION: In production, use a specific version tag instead of the general v17 flag, which pulls the latest release and could result in different | ||
# versions running within the cluster. See tags available at https://hub.docker.com/r/ceph/ceph/tags/. | ||
# If you want to be more precise, you can always use a timestamp tag such quay.io/ceph/ceph:v17.2.6-20230410 | ||
# This tag might not contain a new Ceph version, just security fixes from the underlying operating system, which will reduce vulnerabilities | ||
image: quay.io/ceph/ceph:v17.2.6 | ||
# Whether to allow unsupported versions of Ceph. Currently `pacific`, `quincy`, and `reef` are supported. | ||
# Future versions such as `squid` (v19) would require this to be set to `true`. | ||
# Do not set to true in production. | ||
allowUnsupported: false | ||
# The path on the host where configuration files will be persisted. Must be specified. | ||
# Important: if you reinstall the cluster, make sure you delete this directory from each host or else the mons will fail to start on the new cluster. | ||
# In Minikube, the '/data' directory is configured to persist across reboots. Use "/data/rook" in Minikube environment. | ||
dataDirHostPath: /var/lib/rook | ||
# Whether or not upgrade should continue even if a check fails | ||
# This means Ceph's status could be degraded and we don't recommend upgrading but you might decide otherwise | ||
# Use at your OWN risk | ||
# To understand Rook's upgrade process of Ceph, read https://rook.io/docs/rook/latest/ceph-upgrade.html#ceph-version-upgrades | ||
skipUpgradeChecks: false | ||
# Whether or not continue if PGs are not clean during an upgrade | ||
continueUpgradeAfterChecksEvenIfNotHealthy: false | ||
# WaitTimeoutForHealthyOSDInMinutes defines the time (in minutes) the operator would wait before an OSD can be stopped for upgrade or restart. | ||
# If the timeout exceeds and OSD is not ok to stop, then the operator would skip upgrade for the current OSD and proceed with the next one | ||
# if `continueUpgradeAfterChecksEvenIfNotHealthy` is `false`. If `continueUpgradeAfterChecksEvenIfNotHealthy` is `true`, then operator would | ||
# continue with the upgrade of an OSD even if its not ok to stop after the timeout. This timeout won't be applied if `skipUpgradeChecks` is `true`. | ||
# The default wait timeout is 10 minutes. | ||
waitTimeoutForHealthyOSDInMinutes: 10 | ||
mon: | ||
# Set the number of mons to be started. Generally recommended to be 3. | ||
# For highest availability, an odd number of mons should be specified. | ||
count: 3 | ||
# The mons should be on unique nodes. For production, at least 3 nodes are recommended for this reason. | ||
# Mons should only be allowed on the same node for test environments where data loss is acceptable. | ||
allowMultiplePerNode: false | ||
mgr: | ||
# When higher availability of the mgr is needed, increase the count to 2. | ||
# In that case, one mgr will be active and one in standby. When Ceph updates which | ||
# mgr is active, Rook will update the mgr services to match the active mgr. | ||
count: 2 | ||
allowMultiplePerNode: false | ||
modules: | ||
# Several modules should not need to be included in this list. The "dashboard" and "monitoring" modules | ||
# are already enabled by other settings in the cluster CR. | ||
- name: pg_autoscaler | ||
enabled: true | ||
# enable the ceph dashboard for viewing cluster status | ||
dashboard: | ||
enabled: true | ||
# serve the dashboard under a subpath (useful when you are accessing the dashboard via a reverse proxy) | ||
# urlPrefix: /ceph-dashboard | ||
# serve the dashboard at the given port. | ||
# port: 8443 | ||
# serve the dashboard using SSL | ||
ssl: true | ||
# The url of the Prometheus instance | ||
# prometheusEndpoint: <protocol>://<prometheus-host>:<port> | ||
# Whether SSL should be verified if the Prometheus server is using https | ||
# prometheusEndpointSSLVerify: false | ||
# enable prometheus alerting for cluster | ||
monitoring: | ||
# requires Prometheus to be pre-installed | ||
enabled: false | ||
# Whether to disable the metrics reported by Ceph. If false, the prometheus mgr module and Ceph exporter are enabled. | ||
# If true, the prometheus mgr module and Ceph exporter are both disabled. Default is false. | ||
metricsDisabled: false | ||
network: | ||
connections: | ||
# Whether to encrypt the data in transit across the wire to prevent eavesdropping the data on the network. | ||
# The default is false. When encryption is enabled, all communication between clients and Ceph daemons, or between Ceph daemons will be encrypted. | ||
# When encryption is not enabled, clients still establish a strong initial authentication and data integrity is still validated with a crc check. | ||
# IMPORTANT: Encryption requires the 5.11 kernel for the latest nbd and cephfs drivers. Alternatively for testing only, | ||
# you can set the "mounter: rbd-nbd" in the rbd storage class, or "mounter: fuse" in the cephfs storage class. | ||
# The nbd and fuse drivers are *not* recommended in production since restarting the csi driver pod will disconnect the volumes. | ||
encryption: | ||
enabled: false | ||
# Whether to compress the data in transit across the wire. The default is false. | ||
# Requires Ceph Quincy (v17) or newer. Also see the kernel requirements above for encryption. | ||
compression: | ||
enabled: false | ||
# Whether to require communication over msgr2. If true, the msgr v1 port (6789) will be disabled | ||
# and clients will be required to connect to the Ceph cluster with the v2 port (3300). | ||
# Requires a kernel that supports msgr v2 (kernel 5.11 or CentOS 8.4 or newer). | ||
requireMsgr2: false | ||
# enable host networking | ||
#provider: host | ||
# enable the Multus network provider | ||
#provider: multus | ||
#selectors: | ||
# The selector keys are required to be `public` and `cluster`. | ||
# Based on the configuration, the operator will do the following: | ||
# 1. if only the `public` selector key is specified both public_network and cluster_network Ceph settings will listen on that interface | ||
# 2. if both `public` and `cluster` selector keys are specified the first one will point to 'public_network' flag and the second one to 'cluster_network' | ||
# | ||
# In order to work, each selector value must match a NetworkAttachmentDefinition object in Multus | ||
# | ||
# public: public-conf --> NetworkAttachmentDefinition object name in Multus | ||
# cluster: cluster-conf --> NetworkAttachmentDefinition object name in Multus | ||
# Provide internet protocol version. IPv6, IPv4 or empty string are valid options. Empty string would mean IPv4 | ||
#ipFamily: "IPv6" | ||
# Ceph daemons to listen on both IPv4 and Ipv6 networks | ||
#dualStack: false | ||
# Enable multiClusterService to export the mon and OSD services to peer cluster. | ||
# This is useful to support RBD mirroring between two clusters having overlapping CIDRs. | ||
# Ensure that peer clusters are connected using an MCS API compatible application, like Globalnet Submariner. | ||
#multiClusterService: | ||
# enabled: false | ||
|
||
# enable the crash collector for ceph daemon crash collection | ||
crashCollector: | ||
disable: false | ||
# Uncomment daysToRetain to prune ceph crash entries older than the | ||
# specified number of days. | ||
#daysToRetain: 30 | ||
# enable log collector, daemons will log on files and rotate | ||
logCollector: | ||
enabled: true | ||
periodicity: daily # one of: hourly, daily, weekly, monthly | ||
maxLogSize: 500M # SUFFIX may be 'M' or 'G'. Must be at least 1M. | ||
# automate [data cleanup process](https://github.com/rook/rook/blob/master/Documentation/Storage-Configuration/ceph-teardown.md#delete-the-data-on-hosts) in cluster destruction. | ||
cleanupPolicy: | ||
# Since cluster cleanup is destructive to data, confirmation is required. | ||
# To destroy all Rook data on hosts during uninstall, confirmation must be set to "yes-really-destroy-data". | ||
# This value should only be set when the cluster is about to be deleted. After the confirmation is set, | ||
# Rook will immediately stop configuring the cluster and only wait for the delete command. | ||
# If the empty string is set, Rook will not destroy any data on hosts during uninstall. | ||
confirmation: "" | ||
# sanitizeDisks represents settings for sanitizing OSD disks on cluster deletion | ||
sanitizeDisks: | ||
# method indicates if the entire disk should be sanitized or simply ceph's metadata | ||
# in both case, re-install is possible | ||
# possible choices are 'complete' or 'quick' (default) | ||
method: quick | ||
# dataSource indicate where to get random bytes from to write on the disk | ||
# possible choices are 'zero' (default) or 'random' | ||
# using random sources will consume entropy from the system and will take much more time then the zero source | ||
dataSource: zero | ||
# iteration overwrite N times instead of the default (1) | ||
# takes an integer value | ||
iteration: 1 | ||
# allowUninstallWithVolumes defines how the uninstall should be performed | ||
# If set to true, cephCluster deletion does not wait for the PVs to be deleted. | ||
allowUninstallWithVolumes: false | ||
# To control where various services will be scheduled by kubernetes, use the placement configuration sections below. | ||
# The example under 'all' would have all services scheduled on kubernetes nodes labeled with 'role=storage-node' and | ||
# tolerate taints with a key of 'storage-node'. | ||
# placement: | ||
# all: | ||
# nodeAffinity: | ||
# requiredDuringSchedulingIgnoredDuringExecution: | ||
# nodeSelectorTerms: | ||
# - matchExpressions: | ||
# - key: role | ||
# operator: In | ||
# values: | ||
# - storage-node | ||
# podAffinity: | ||
# podAntiAffinity: | ||
# topologySpreadConstraints: | ||
# tolerations: | ||
# - key: storage-node | ||
# operator: Exists | ||
# The above placement information can also be specified for mon, osd, and mgr components | ||
# mon: | ||
# Monitor deployments may contain an anti-affinity rule for avoiding monitor | ||
# collocation on the same node. This is a required rule when host network is used | ||
# or when AllowMultiplePerNode is false. Otherwise this anti-affinity rule is a | ||
# preferred rule with weight: 50. | ||
# osd: | ||
# prepareosd: | ||
# mgr: | ||
# cleanup: | ||
annotations: | ||
# all: | ||
# mon: | ||
# osd: | ||
# cleanup: | ||
# prepareosd: | ||
# clusterMetadata annotations will be applied to only `rook-ceph-mon-endpoints` configmap and the `rook-ceph-mon` and `rook-ceph-admin-keyring` secrets. | ||
# And clusterMetadata annotations will not be merged with `all` annotations. | ||
# clusterMetadata: | ||
# kubed.appscode.com/sync: "true" | ||
# If no mgr annotations are set, prometheus scrape annotations will be set by default. | ||
# mgr: | ||
labels: | ||
# all: | ||
# mon: | ||
# osd: | ||
# cleanup: | ||
# mgr: | ||
# prepareosd: | ||
# monitoring is a list of key-value pairs. It is injected into all the monitoring resources created by operator. | ||
# These labels can be passed as LabelSelector to Prometheus | ||
# monitoring: | ||
# crashcollector: | ||
resources: | ||
#The requests and limits set here, allow the mgr pod to use half of one CPU core and 1 gigabyte of memory | ||
# mgr: | ||
# limits: | ||
# cpu: "500m" | ||
# memory: "1024Mi" | ||
# requests: | ||
# cpu: "500m" | ||
# memory: "1024Mi" | ||
# The above example requests/limits can also be added to the other components | ||
# mon: | ||
# osd: | ||
# For OSD it also is a possible to specify requests/limits based on device class | ||
# osd-hdd: | ||
# osd-ssd: | ||
# osd-nvme: | ||
# prepareosd: | ||
# mgr-sidecar: | ||
# crashcollector: | ||
# logcollector: | ||
# cleanup: | ||
# exporter: | ||
# The option to automatically remove OSDs that are out and are safe to destroy. | ||
removeOSDsIfOutAndSafeToRemove: false | ||
priorityClassNames: | ||
#all: rook-ceph-default-priority-class | ||
mon: system-node-critical | ||
osd: system-node-critical | ||
mgr: system-cluster-critical | ||
#crashcollector: rook-ceph-crashcollector-priority-class | ||
storage: # cluster level storage configuration and selection | ||
useAllNodes: true | ||
useAllDevices: true | ||
#deviceFilter: | ||
config: | ||
# crushRoot: "custom-root" # specify a non-default root label for the CRUSH map | ||
# metadataDevice: "md0" # specify a non-rotational storage so ceph-volume will use it as block db device of bluestore. | ||
# databaseSizeMB: "1024" # uncomment if the disks are smaller than 100 GB | ||
# osdsPerDevice: "1" # this value can be overridden at the node or device level | ||
# encryptedDevice: "true" # the default value for this option is "false" | ||
# Individual nodes and their config can be specified as well, but 'useAllNodes' above must be set to false. Then, only the named | ||
# nodes below will be used as storage resources. Each node's 'name' field should match their 'kubernetes.io/hostname' label. | ||
# nodes: | ||
# - name: "172.17.4.201" | ||
# devices: # specific devices to use for storage can be specified for each node | ||
# - name: "sdb" | ||
# - name: "nvme01" # multiple osds can be created on high performance devices | ||
# config: | ||
# osdsPerDevice: "5" | ||
# - name: "/dev/disk/by-id/ata-ST4000DM004-XXXX" # devices can be specified using full udev paths | ||
# config: # configuration can be specified at the node level which overrides the cluster level config | ||
# - name: "172.17.4.301" | ||
# deviceFilter: "^sd." | ||
# when onlyApplyOSDPlacement is false, will merge both placement.All() and placement.osd | ||
onlyApplyOSDPlacement: false | ||
# Time for which an OSD pod will sleep before restarting, if it stopped due to flapping | ||
# flappingRestartIntervalHours: 24 | ||
# The section for configuring management of daemon disruptions during upgrade or fencing. | ||
disruptionManagement: | ||
# If true, the operator will create and manage PodDisruptionBudgets for OSD, Mon, RGW, and MDS daemons. OSD PDBs are managed dynamically | ||
# via the strategy outlined in the [design](https://github.com/rook/rook/blob/master/design/ceph/ceph-managed-disruptionbudgets.md). The operator will | ||
# block eviction of OSDs by default and unblock them safely when drains are detected. | ||
managePodBudgets: true | ||
# A duration in minutes that determines how long an entire failureDomain like `region/zone/host` will be held in `noout` (in addition to the | ||
# default DOWN/OUT interval) when it is draining. This is only relevant when `managePodBudgets` is `true`. The default value is `30` minutes. | ||
osdMaintenanceTimeout: 30 | ||
# A duration in minutes that the operator will wait for the placement groups to become healthy (active+clean) after a drain was completed and OSDs came back up. | ||
# Operator will continue with the next drain if the timeout exceeds. It only works if `managePodBudgets` is `true`. | ||
# No values or 0 means that the operator will wait until the placement groups are healthy before unblocking the next drain. | ||
pgHealthCheckTimeout: 0 | ||
|
||
# healthChecks | ||
# Valid values for daemons are 'mon', 'osd', 'status' | ||
healthCheck: | ||
daemonHealth: | ||
mon: | ||
disabled: false | ||
interval: 45s | ||
osd: | ||
disabled: false | ||
interval: 60s | ||
status: | ||
disabled: false | ||
interval: 60s | ||
# Change pod liveness probe timing or threshold values. Works for all mon,mgr,osd daemons. | ||
livenessProbe: | ||
mon: | ||
disabled: false | ||
mgr: | ||
disabled: false | ||
osd: | ||
disabled: false | ||
# Change pod startup probe timing or threshold values. Works for all mon,mgr,osd daemons. | ||
startupProbe: | ||
mon: | ||
disabled: false | ||
mgr: | ||
disabled: false | ||
osd: | ||
disabled: false | ||
|
Oops, something went wrong.