Skip to content

Kermit for RSX180 and RSX280 Operating Systems

Notifications You must be signed in to change notification settings

hperaza/Kermit-180

Repository files navigation

KERMIT for RSX180 and RSX280

Here you can find the CP/M Kermit-80 ported to the RSX180/280 OS.

Kermit-180 has been tested on a P112 (Z180) machine running RSX180 and on a Z280RC (Z280) machine running RSX280.

Kermit-180 Capabilities at a glance

Capability Implemented
Local operation Yes
Remote operation Yes
Login scripts Yes, limited
Transfer text files Yes
Transfer binary files Yes
Wildcard send Yes
File transfer interruption Yes
Filename collision avoidance Yes
Can time out Yes
8th-bit prefixing Yes
Repeat count prefixing No
Alternate block checks Yes
Terminal emulation Yes, limited
Communication settings If supported by the terminal driver
Support for dial-out modems No
Transmit BREAK If supported by the terminal driver
IBM communication Yes
Transaction logging No
Debug logging No
Session logging Yes
Raw file transmit Yes
Act as server Yes
Talk to server Yes
Advanced commands for servers Yes
Command/init files Yes
Command macros No
Local file management Yes
Handle file attributes No
Long packets No
International Character Sets No
Sliding Windows No
Printer control No

Quick start guide

  1. Start Kermit at the PC side and setup it accordingly, the following settings were used with C-Kermit 9.0.302 under Linux:
    set line /dev/ttyUSB1 (or whatever line your machine is connected to)
    set speed 19200 (this is the default for the Z280RC quad-serial board under RSX280)
    set attributes off
    set parity space (or set parity none)
    set file type binary
    set carrier-watch off
    set flow-control none
    set control-character prefixed all
    set file patterns off
    set transfer mode manual
    To avoid having to type the above commands every time, you can save them into a text file and then use the Kermit's take command to execute them.

  2. Start Kermit-180 on the RSX180/280 side:
    run $kermit (if Kermit-180 is not installed)
    ker (if Kermit-180 is installed as ...KER)
    Once it is running, setup the communication parameters. The following settings were used on a Z280RC running RSX280:
    set line tt3: (or whatever line the Z280RC is connected to the PC)
    set parity space (or set parity none, but must match the PC settings above)
    set file-mode binary
    As with the PC Kermit, you can save the above command sequence into a text file for later execution via the take command. If you name the file kermit.ini and place it into your user's directory, Kermit-180 will execute it automatically on startup.

  3. You can now use the send command on the PC side and the get command on the RSX280 side to transfer a file from the PC to the Z280RC. Do the opposite to send a file from the Z280RC to the PC.

  4. Best is just to put the PC Kermit in server mode. Then, you can send and receive files by only entering commands at RSX180/280 terminal. E.g.
    send examp.cmd to send a file to the PC
    get kermit.tsk to fetch a file from the PC
    remote dir to browse the PC directory
    dir to browse the local RSX180/280 directory
    etc.

Bugs and Limitations

Kermit-180 is built by default as a non-privileged task, meaning that in local mode it cannot change the characteristics of the terminal used for communications unless the terminal has been set to public by the system administrator. Specifically, Kermit-180 needs to set the terminal mode to slave with echo disabled, and those are privileged operations for terminals other than the user's current one. Remote mode does not suffer from that limitation, as it uses the user's current terminal for communications.

The filename completion (e.g. for DIR or ERA commands) is not working fully correctly yet: pressing ESC or TAB a second time appends part of the file extension again to the completed file name, etc.

The current version of Kermit-180 is not able to process file attribute information, and therefore the correct file type (text or binary) has to be set manually at both ends before starting the transfer.

Some modern Kermit programs (e.g. C-Kermit 9.0 on Linux) don't prefix all control characters by default as the protocol specifies, and therefore file transfers the PC to the Z280RC may fail randomly. The solution is to use the set control-character prefixed all command at the PC side. I'd recommend using set file patterns off and set transfer mode manual as well, otherwise C-Kermit will try to switch automatically to ascii mode when transferring text files in binary mode without Kermit-180 being aware of the change. The result is a text file with duplicated carriage return characters being received at the RSX180/280 side if the file at the PC side already had CR/LF line endings.

About

Kermit for RSX180 and RSX280 Operating Systems

Topics

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published