Support configuration changes without reopening #141
Comments
@reillyeon Thank you. So far on the eep-home-webtools we found a partial workaround in the meantime. We close the port and reopen it with the new baud rate. I say partial because there are some USB2Serial controllers commonly used on ESP boards that become irresponsive after closing the port, to that workaround does not work for them. Speaking of flushing, the Espressiff guys on their flashing tool build with python flush the input buffers after changing the baud rate and after certain operations to get rid of some unneeded data. I believe the current api does not support a flushInput() method on the port, does it? that'd be a nice addition too. |
This code will flush the input stream, let reader = port.readable.getReader();
// Do whatever reading you want. When you want to flush the read buffer,
await reader.cancel();
// port.readable is replaced with a new ReadableStream.
reader = port.readable.getReader();
// Continue reading. |
I'm really sad that this important feature still does not exist in the standard. Port reopening is not a reliable solution, because:
|
I am also interested in a reconfigure option to be able to properly emulate a DMX signal using a UART driven by the WebSerial interface. The DMX protocol differs from the traditional RS485 transmission protocol in that it includes a "break" sequence that indicates that a message is about to be sent. Many DMX applications that use serial output emulate this break sequence by changing the baud rate to a much slower rate, broadcasting a At the moment, reconnecting the port takes way too long (as noted by @Azq2) and the signals are not close enough temporally for the DMX fixtures to recognize the break sequence. See this Chromium feature request for more details. |
@wmmiii are you aware that you can send break signals of arbitrary lengths using the Using this function you can set break to true, wait a specified time (e.g. 200ms) then set break to false. I have used this approach with https://ninjaterm.mbedded.ninja/ and it seems to work well. |
Thanks @gbmhunter! I tried to use this however
I also tried to set the signals before I use the port (right after opening). While it doesn't throw an error my UART does not recognize the signal. I don't have a logic analyzer to see what is going on on the wire though. Note: Here is how I am setting signals (in both attempts) await (port as any).setSignals({ break: true });
await new Promise((resolve) => setTimeout(resolve, 200));
// Do the writing here I tried to search for |
@wmmiii you should be able to use I send the break signal in NinjaTerm in App.tsx (using an open port) in the function starting on Line 880 (in the latest version on main), see https://github.com/gbmhunter/NinjaTerm/blob/v4.18.0/src/model/App.tsx#L880 for the example you could look at. |
+1 to |
From #71,
A
reconfigure()
method seems very reasonable. It would probably work similarly toclose()
in that it requires the readable and writable streams to be closed. It looks like operating systems provide some flexibility around whether data is flushed and drained when the port is reconfigured. For transmitted data the requirement that writable is closed already handles that. For received data I think we can make the decision to only support flushing the read buffers when reconfiguring the port in order to avoid the application encountering corrupted data.The text was updated successfully, but these errors were encountered: