Skip to content

Commit

Permalink
Update and rename FREQ.TXT to ANSYS/FREQ.TXT
Browse files Browse the repository at this point in the history
  • Loading branch information
ThomasFabula authored Apr 17, 2024
1 parent 786bac8 commit 51965c5
Showing 1 changed file with 22 additions and 22 deletions.
44 changes: 22 additions & 22 deletions FREQ.TXT → ANSYS/FREQ.TXT
Original file line number Diff line number Diff line change
Expand Up @@ -2,105 +2,105 @@

Sensortemperatur/Eigenfrequenzen.

Temperatur�berh�hung (K) 0.
Temperaturüberhöhung (K) 0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 4223.0 21 1 1
2 11727. 21 2 2

Temperatur�berh�hung (K) 10.0.
Temperaturüberhöhung (K) 10.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 3470.8 21 1 1

Temperatur�berh�hung (K) 15.0.
Temperaturüberhöhung (K) 15.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 2986.1 21 1 1
2 10202. 21 2 2

Temperatur�berh�hung (K) 20.0.
Temperaturüberhöhung (K) 20.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 2370.6 21 1 1
2 9586.4 21 2 2

Temperatur�berh�hung (K) 21.0.
Temperaturüberhöhung (K) 21.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 2223.1 21 1 1
2 9455.2 21 2 2

Temperatur�berh�hung (K) 22.0.
Temperaturüberhöhung (K) 22.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 2063.1 21 1 1
2 9320.9 21 2 2

Temperatur�berh�hung (K) 23.0.
Temperaturüberhöhung (K) 23.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 1888.0 21 1 1
2 9183.6 21 2 2

Temperatur�berh�hung (K) 24.0.
Temperaturüberhöhung (K) 24.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 1693.6 21 1 1
2 9043.2 21 2 2

Temperatur�berh�hung (K) 25.0.
Temperaturüberhöhung (K) 25.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 1473.5 21 1 1
2 8899.9 21 2 2

Temperatur�berh�hung (K) 26.0.
Temperaturüberhöhung (K) 26.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 1182.3 21 1 1
2 Temperatur�berh�hung 21 2 2
2 Temperaturüberhöhung 21 2 2

Temperatur�berh�hung (K) 27.0.
TemperaturÏberhÎhung (K) 27.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 925.07 21 1 1
2 8582.3 21 2 2

Temperatur�berh�hung (K) 29.0.
Temperaturüberhöhung (K) 29.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 1651.6 21 1 1
2 8475.7 21 2 2

Temperatur�berh�hung (K) 31.0.
Temperaturüberhöhung (K) 31.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 2434.8 21 1 1
2 8458.5 21 2 2

Temperatur�berh�hung (K) 33.0.
Temperaturüberhöhung (K) 33.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 3050.0 21 1 1
2 8450.4 21 2 2

Temperatur�berh�hung (K) 35.0.
Temperaturüberhöhung (K) 35.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 3576.2 21 1 1
2 8447.5 21 2 2

Temperatur�berh�hung (K) 40.0.
Temperaturüberhöhung (K) 40.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 4648.0 21 1 1
2 8438.2 21 2 2

Temperatur�berh�hung (K) 45.0.
Temperaturüberhöhung (K) 45.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 5530.2 21 1 1
2 8433.0 21 2 2

Temperatur�berh�hung (K) 5.0.
Temperaturüberhöhung (K) 5.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 3875.2 21 1 1
2 11265. 21 2 2

Temperatur�berh�hung (K) 50.0.
Temperaturüberhöhung (K) 50.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 6296.0 21 1 1
2 8433.0 21 2 2
Temperatur�berh�hung (K) 55.0.
Temperaturüberhöhung (K) 55.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 6884.5 21 1 1
2 8426.8 21 2 2

Temperatur�berh�hung (K) 60.0.
Temperaturüberhöhung (K) 60.0.
SET TIME/FREQ LOAD STEP SUBSTEP CUMULATIVE
1 7414.9 21 1 1
2 8423.1 21 2 2

0 comments on commit 51965c5