Abstract
Introduction
Fractures of the distal radius in elderly patients are often associated with metaphyseal defects that can lead to collapse, malunion and therefore decreased function. An alternative approach to simple reduction is to fill the defects with materials that can provide structural support.
Methods
We used synthetic hydroxyapatite (HA) in unstable fractures of the distal radius in thirty-one elderly patients, of which four patients lost to follow-up, leaving twenty-seven patients for this study. All subjects underwent closed reduction with K-wire fixation and HA augmentation. They were followed up at 8- and 16-week intervals post-operatively to assess the functional outcome using patient-related wrist evaluation [PRWE], clinical outcome and radiological outcome.
Results
At mean 16 weeks, our results show that patients treated with this method showed no metaphyseal defect, no collapse and had satisfactory clinical outcome as assessed by PRWE.
Conclusion
We believe that fixation with hydroxyapatite augmentation for fractures of the distal radius in elderly patients is an attractive therapeutic option. This experience has changed our clinical practice.
Similar content being viewed by others
References
Solgaard W, Petersen SV (1985) Epidemiology of distal radius fractures. Acta Orthop Scand 56:391–393
Dobyns JH, Linscheid RL (2006) Fractures and dislocations of wrist. In: Rockwood CA Jr., Green DP (eds), Fractures in adults, vol 1, 4th edn. Lippincott Williams and Wilkins, p 769–791
Colles A (1972) The classic: on the fracture of the carpal extremity of the radius. Clin Orthop 83:3–5 (Reprinted from the original 1814 article)
Sarmiento A, Pratt GW, Berry NC, Sinclair WF (1975) Colles’ fractures. Functional bracing in supination. J Bone Joint Surg Am 57(3):311–317
Jupiter JB (1991) Current concepts review: fractures of the distal end of the radius. J Bone Joint Surg Am 73(3):461–469
Cooney WP, Linscheid RL, Dobyns JH (1979) External pins fixation for unstable Colles’ fracture. J Bone Joint Surg Am 61:840–845
Cooney WP III, Dobyns JH, Llnscbeld RL (1975) Complications of Colles’ fractures complications. J Bone Joint Surg Am 57(3):311–317
Willcox N, Kurta I, Menez D (2005) Treatment of distal radial fractures with grafting and K-wiring. Acta Orthop Belg 71:36–40
Tyllianakis ME, Panagopoulos A, Giannikas D, Megas P, Lambiris E (2006) Graft-supplemented, augmented external fixation in the treatment of intra-articular distal radial fractures. Orthopedics 29(2):139
Goulet JA, Senunas LE, DeSilva GL, Greenfield ML (1997) Autogenous iliac crest bone graft: complications and functional assessment. Clin Orthop Relat Res 339:76–81
Arrington ED, Smith WJ (1996) Complications of iliac crest bone graft harvesting. Clin Orthop Relat Res 329:300–309
Wolfe SW, Pike L (1999) Augmentation of distal radius fracture fixation with coralline hydroxyapatite bone graft substitute. J Hand Surg 24:816
Frykman GK (1967) Fracture of the distal radius including sequelae–shoulder–hand–finger syndrome: disturbance in the distal radioulnar joint and impairment of nerve function. Acta Orthop Scand Suppl 108:1–153
Changulani M, Okonkwo U (2008) Outcome evaluation measures for wrist and hand—which one to choose? Int Orthop 32(1):1–6
Gajdosik RL, Bohannon RW (1987) Clinical measurement of range of motion: review of goniometry emphasizing reliability and validity. Phys Ther 67(12):1867–1872
Ng CY, McQueen MM (2011) What are the radiological predictors of functional outcome following fractures of the distal radius? J Bone Joint Surg Br 93(2):145–150
Dorozhkin SV (2009) Calcium orthophosphate cements and concretes. Materials 2:221–291
Finkemeier CG (2002) Bone-grafting and bone-graft substitutes. J Bone Joint Surg Am 84:454–464
Brandoff JF (2002) Contemporary options in synthetic bone graft alternatives. J Trauma 53:1103–1108
Dickson KF, Friedman J, Buchholz JG, Flandry FD (2002) The use of bone source hydroxyapatite cement for traumatic metaphyseal bone void filling. J Trauma 53:1103–1108
Sanchez-Sotelo J, Munuera L, Madero R (2000) Treatment of fractures of the distal radius with a remodellable bone cement—a prospective, randomised study using Norian SRS. J Bone Joint Surg Br 82(B):856–863
Liverneaux P, Vernet P, Robert C, Diacono P (2006) Cement pinning of osteoporotic distal radius fractures with an injectable calcium phosphate bone substitute: report of 6 cases. Eur J Orthop Surg Traumatol 16(1):10–16
Liverneaux PA (2006) Osteoporotic distal radius curettage-filling with an injectable calcium phosphate cement. A cadaveric study. Eur J Orthop Surg Traumatol 15(1):1–6
Conflict of interest
The authors declare that there is no conflict of interest regarding this article.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Hegde, C., Shetty, V., Wasnik, S. et al. Use of bone graft substitute in the treatment for distal radius fractures in elderly. Eur J Orthop Surg Traumatol 23, 651–656 (2013). https://doi.org/10.1007/s00590-012-1057-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00590-012-1057-1