In vivo comparison of scanning technique and wavelength in laser Doppler perfusion imaging: Measurement in knee ligaments of adult rabbits

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

At present, there are only two laser Doppler perfusion imaging systems (LDls) manufactured for medical applications: a ‘tepwise’ and a ‘continuous’ scanning LDI. The stepwise scanning LDI has previously been investigated and compared with coloured microsphere determined standardised flow. The continuous scanning LDI is investigated and compared with the stepwise scanning LDI for its ability to measure in vivo, hypoaemic, ligament tissue blood flow changes. The continuous scanning system was supplied with two lasers, red and near infrared (NIR), allowing for additional assessment of the effect of wavelength on imaging ligament perfusion. Perfusion images were obtained from surgically exposed rabbit medial collateral ligaments (MCL). Continuous and stepwise LDI scans were compared using correlation and linear regression analysis of image averages and standard deviations. Using the same method of analysis, LDI measurements using red and NIR lasers indicated a high degree of correlation, at least over the ranges of perfusion assessed, indicating that red and NIR lasers measure similar regions of flow in the rabbit MCL. These experiments confirm that both LDI techniques provide a valid in vivo measure of dynamic changes in connective tissue perfusion and could have significant impact on the understanding and treatment of joint injury and arthritis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price includes VAT (Canada)

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Arnfield, M. R., Matthew, R. P., Tulip, J. andMcPhee, M. S. (1992): ‘Analysis of tissue optical coefficients using an approximate equation valid for comparable absorption and scattering’,Phys. Med. Biol.,37, pp. 1219–1230

    Article  Google Scholar 

  • Barnett, N. J., Dougherty, G. andPettinger, S. J. (1990): ‘Comparative study of two laser Doppler blood flowmeters’,J. Mech. Eng. Technol. 14, pp. 243–249

    Google Scholar 

  • Bray, R. C. (1995): ‘Blood supply of ligaments: A brief overview’,Int. Orthop.,3, pp. 39–48

    Google Scholar 

  • Bray, R., Forrester, K., McDougall, J. J., Damji, A. andFerrell, W. R. (1996): ‘Evaluation of laser Doppler imaging to measure blood flow in knee ligaments of adult rabbits’,Med. Biol. Eng. Comput.,34, pp. 227–231

    Google Scholar 

  • Doschak, M., Bray, R. andTyberg, J. (1994): ‘Elevation of blood flow in an ACL-deficient rabbit knee is associated with deterioration of MCL biomechanical properties’, Proc. Can. Ortho. Res. Soc. (Winnipeg, Manitoba)

  • Dunlop, I., McCarthy, J. A., Ogata, K. andShively, R. A. (1989): ‘Quantification of the perfusion of the anterior cruciate ligament and the effects of stress and injury to supporting structures’,Am. J. Sports Med.,17, 808–810

    Google Scholar 

  • Essex, T. J. H. andByrne, P. O. (1991): ‘A laser Doppler scanner for imaging blood flow in skin’,J. Biomed. Eng.,14, pp. 189–194

    Google Scholar 

  • Jakobsson, A. andNilsson, G. E. (1992): ‘Prediction of sampling depth and photon pathlength in laser Doppler flowmetry’,Med. Biol. Eng. Comput.,31, pp. 301–307

    Article  Google Scholar 

  • Kalbfleisch, J. G. (1985): ‘Probability and statistical inference Vol. 1: probability’, 2nd Ed. (Springer-Verlag, New York, USA)

    Google Scholar 

  • Kalbfleisch, J. G. (1985): ‘Probability and statistical inference Vol. 2: statistical inference’, 2nd Ed. (Springer-Verlag, New York, USA)

    Google Scholar 

  • Linsberg, P. J., O’Neil, J. T., Paakkari, I. A., Hallenbeck, J. M. andFeuterstein, G. (1989): ‘Validation of laser Doppler flowmetry in measurement of spinal cord blood flow’,Am. J. Physiol. 257, pp. H674-H680

    Google Scholar 

  • Nilsson, G. E., Tenland, T. andOberg, P. A. (1980): ‘A new instrument for continuous measurement of tissue blood flow by light beating spectroscopy’,IEEE Trans. Biomed. Eng.,27, pp. 597–604

    Google Scholar 

  • Nilsson, G. E. (1984): ‘Signal processor for laser Doppler flowmeters’,Med. Biol. Eng. Comput.,22, pp. 343–348

    Article  Google Scholar 

  • Shepherd, A. P., Riedel, G. L., Kiel, J. W., Haumschild, D. J. andMaxwell, L. C. (1987): ‘Evaluation of an infrared laser Doppler flowmeter’,Am. J. Physiol.,252, pp. G832-G839

    Google Scholar 

  • Smits, G. J., Roman, R. J. andLombard, J. H. (1986): ‘Evaluation of laser Doppler flowmetry as a measure of tissue blood flow’,J. Appl. Physiol.,61, pp. 666–672

    Google Scholar 

  • Stern, M. D. (1975): ‘In vivo evaluation of microcirculation by coherent light scattering’,Nature,254, pp. 56–58

    Article  Google Scholar 

  • Wårdell, K., Jakobsson, A. andNilsson, G. E. (1993): ‘Laser Doppler perfusion imaging by dynamic light scattering’,IEEE Trans. Biomed. Eng.,40, pp. 309–316

    Article  Google Scholar 

  • Watkins, D. andHolloway, G. A. Jr. (1978): ‘An instrument to measure cutaneous blood flow using the Doppler shift of laser light’,IEEE Trans. Biomed. Eng.,25, pp. 28–33

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. Bray.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Forrester, K., Doschak, M. & Bray, R. In vivo comparison of scanning technique and wavelength in laser Doppler perfusion imaging: Measurement in knee ligaments of adult rabbits. Med. Biol. Eng. Comput. 35, 581–586 (1997). https://doi.org/10.1007/BF02510964

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02510964

Keywords

Navigation