The accuracy of the out-of-field dose calculations using a model based algorithm in a commercial treatment planning system
- PMID: 24925858
- DOI: 10.1088/0031-9155/59/13/N113
The accuracy of the out-of-field dose calculations using a model based algorithm in a commercial treatment planning system
Abstract
The out-of-field dose can be clinically important as it relates to the dose of the organ-at-risk, although the accuracy of its calculation in commercial radiotherapy treatment planning systems (TPSs) receives less attention. This study evaluates the uncertainties of out-of-field dose calculated with a model based dose calculation algorithm, anisotropic analytical algorithm (AAA), implemented in a commercial radiotherapy TPS, Varian Eclipse V10, by using Monte Carlo (MC) simulations, in which the entire accelerator head is modeled including the multi-leaf collimators. The MC calculated out-of-field doses were validated by experimental measurements. The dose calculations were performed in a water phantom as well as CT based patient geometries and both static and highly modulated intensity-modulated radiation therapy (IMRT) fields were evaluated. We compared the calculated out-of-field doses, defined as lower than 5% of the prescription dose, in four H&N cancer patients and two lung cancer patients treated with volumetric modulated arc therapy (VMAT) and IMRT techniques. The results show that the discrepancy of calculated out-of-field dose profiles between AAA and the MC depends on the depth and is generally less than 1% for in water phantom comparisons and in CT based patient dose calculations for static field and IMRT. In cases of VMAT plans, the difference between AAA and MC is <0.5%. The clinical impact resulting from the error on the calculated organ doses were analyzed by using dose-volume histograms. Although the AAA algorithm significantly underestimated the out-of-field doses, the clinical impact on the calculated organ doses in out-of-field regions may not be significant in practice due to very low out-of-field doses relative to the target dose.
Similar articles
-
AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code PENELOPE.Radiother Oncol. 2009 Oct;93(1):94-101. doi: 10.1016/j.radonc.2009.05.010. Epub 2009 Jun 21. Radiother Oncol. 2009. PMID: 19541380
-
A simple technique to improve calculated skin dose accuracy in a commercial treatment planning system.J Appl Clin Med Phys. 2018 Mar;19(2):191-197. doi: 10.1002/acm2.12275. Epub 2018 Feb 6. J Appl Clin Med Phys. 2018. PMID: 29411506 Free PMC article.
-
Dosimetric impact of Acuros XB deterministic radiation transport algorithm for heterogeneous dose calculation in lung cancer.Med Phys. 2013 May;40(5):051710. doi: 10.1118/1.4802216. Med Phys. 2013. PMID: 23635258 Free PMC article.
-
Influence of the jaw tracking technique on the dose calculation accuracy of small field VMAT plans.J Appl Clin Med Phys. 2017 Jan;18(1):186-195. doi: 10.1002/acm2.12029. Epub 2017 Jan 3. J Appl Clin Med Phys. 2017. PMID: 28291941 Free PMC article. Review.
-
High-density dental implants and radiotherapy planning: evaluation of effects on dose distribution using pencil beam convolution algorithm and Monte Carlo method.J Appl Clin Med Phys. 2015 Sep 8;16(5):46–52. doi: 10.1120/jacmp.v16i5.5612. J Appl Clin Med Phys. 2015. PMID: 26699323 Free PMC article. Review.
Cited by
-
Comparison of normal tissue dose calculation methods for epidemiological studies of radiotherapy patients.J Radiol Prot. 2018 Jun;38(2):775-792. doi: 10.1088/1361-6498/aabd4f. Epub 2018 Apr 11. J Radiol Prot. 2018. PMID: 29637904 Free PMC article.
-
Out-of-field doses from radiotherapy using photon beams: A comparative study for a pediatric renal treatment.J Appl Clin Med Phys. 2021 Mar;22(3):94-106. doi: 10.1002/acm2.13182. Epub 2021 Feb 5. J Appl Clin Med Phys. 2021. PMID: 33547766 Free PMC article.
-
Measurement and modeling of out-of-field doses from various advanced post-mastectomy radiotherapy techniques.Phys Med Biol. 2017 Nov 13;62(23):9039-9053. doi: 10.1088/1361-6560/aa94b5. Phys Med Biol. 2017. PMID: 29048329 Free PMC article.
-
Comparison of Two RapidArc Delivery Strategies in Stereotactic Body Radiotherapy of Peripheral Lung Cancer with Flattening Filter Free Beams.PLoS One. 2015 Jul 1;10(7):e0127501. doi: 10.1371/journal.pone.0127501. eCollection 2015. PLoS One. 2015. PMID: 26131554 Free PMC article.
-
Estimating the uncertainty of calculated out-of-field organ dose from a commercial treatment planning system.J Appl Clin Med Phys. 2018 Jul;19(4):319-324. doi: 10.1002/acm2.12367. Epub 2018 Jun 12. J Appl Clin Med Phys. 2018. PMID: 29896876 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources