Rapid delivery of stereotactic radiotherapy for peripheral lung tumors using volumetric intensity-modulated arcs
- PMID: 19552979
- DOI: 10.1016/j.radonc.2009.05.020
Rapid delivery of stereotactic radiotherapy for peripheral lung tumors using volumetric intensity-modulated arcs
Abstract
The delivery of high dose conventional stereotactic body radiotherapy (SBRT) for patients with stage I lung tumors generally takes 30-45min per fraction. The novel volumetric intensity-modulated arc therapy (RA) for planning and delivery enabled much faster treatment for three patients with different fractionation schemes. This reduces the risk of intrafraction motion and is more patient friendly. In addition, in comparison to the conventional plans using 10 static non-coplanar fields, RA plans achieved superior dose conformity around the PTV and reduced chest wall doses.
Similar articles
-
Stereotactic radiotherapy for peripheral lung tumors: a comparison of volumetric modulated arc therapy with 3 other delivery techniques.Radiother Oncol. 2010 Dec;97(3):437-42. doi: 10.1016/j.radonc.2010.09.027. Epub 2010 Nov 11. Radiother Oncol. 2010. PMID: 21074878
-
Does intensity-modulated stereotactic radiotherapy achieve superior target conformity than conventional stereotactic radiotherapy in different intracranial tumours?Clin Oncol (R Coll Radiol). 2009 Jun;21(5):408-16. doi: 10.1016/j.clon.2009.02.002. Epub 2009 Mar 5. Clin Oncol (R Coll Radiol). 2009. PMID: 19268555
-
Volumetric intensity-modulated arc therapy vs. conventional IMRT in head-and-neck cancer: a comparative planning and dosimetric study.Int J Radiat Oncol Biol Phys. 2009 May 1;74(1):252-9. doi: 10.1016/j.ijrobp.2008.12.033. Int J Radiat Oncol Biol Phys. 2009. PMID: 19362244
-
Stereotactic radiotherapy for nonsmall cell lung cancer.Curr Opin Pulm Med. 2008 Jul;14(4):297-302. doi: 10.1097/MCP.0b013e328302405a. Curr Opin Pulm Med. 2008. PMID: 18520262 Review.
-
Altered fractionation in radiotherapy: from radiobiological rationale to therapeutic gain.Cancer Treat Rev. 2010 Dec;36(8):606-14. doi: 10.1016/j.ctrv.2010.04.004. Epub 2010 May 21. Cancer Treat Rev. 2010. PMID: 20494524 Review.
Cited by
-
Asymmetric margin setting at the cranial and caudal sides in respiratory gated and non-gated stereotactic body radiotherapy for lung cancer.Br J Radiol. 2016;89(1059):20150499. doi: 10.1259/bjr.20150499. Epub 2015 Dec 23. Br J Radiol. 2016. PMID: 26693594 Free PMC article.
-
Stereotactic body radiotherapy for early-stage lung cancer: a systematic review on the choice of photon energy and linac flattened/unflattened beams.Radiat Oncol. 2024 Jan 2;19(1):1. doi: 10.1186/s13014-023-02392-4. Radiat Oncol. 2024. PMID: 38167095 Free PMC article. Review.
-
A treatment-planning comparison of three beam arrangement strategies for stereotactic body radiation therapy for centrally located lung tumors using volumetric-modulated arc therapy.J Radiat Res. 2016 Jun;57(3):273-9. doi: 10.1093/jrr/rrv105. Epub 2016 Mar 6. J Radiat Res. 2016. PMID: 26951076 Free PMC article.
-
Stereotactic body radiotherapy in lung cancer: a contemporary review.Pathol Oncol Res. 2024 Feb 27;30:1611709. doi: 10.3389/pore.2024.1611709. eCollection 2024. Pathol Oncol Res. 2024. PMID: 38476352 Free PMC article. Review.
-
Influence of the jaw tracking technique on the dose calculation accuracy of small field VMAT plans.J Appl Clin Med Phys. 2017 Jan;18(1):186-195. doi: 10.1002/acm2.12029. Epub 2017 Jan 3. J Appl Clin Med Phys. 2017. PMID: 28291941 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical