How far droplets can move in indoor environments--revisiting the Wells evaporation-falling curve
- PMID: 17542834
- DOI: 10.1111/j.1600-0668.2007.00469.x
How far droplets can move in indoor environments--revisiting the Wells evaporation-falling curve
Abstract
A large number of infectious diseases are believed to be transmitted between people via large droplets and by airborne routes. An understanding of evaporation and dispersion of droplets and droplet nuclei is not only significant for developing effective engineering control methods for infectious diseases but also for exploring the basic transmission mechanisms of the infectious diseases. How far droplets can move is related to how far droplet-borne diseases can transmit. A simple physical model is developed and used here to investigate the evaporation and movement of droplets expelled during respiratory activities; in particular, the well-known Wells evaporation-falling curve of droplets is revisited considering the effect of relative humidity, air speed, and respiratory jets. Our simple model considers the movement of exhaled air, as well as the evaporation and movement of a single droplet. Exhaled air is treated as a steady-state non-isothermal (warm) jet horizontally issuing into stagnant surrounding air. A droplet is assumed to evaporate and move in this non-isothermal jet. Calculations are performed for both pure water droplets and droplets of sodium chloride (physiological saline) solution (0.9% w/v). We calculate the droplet lifetimes and how droplet size changes, as well as how far the droplets travel in different relative humidities. Our results indicate that a droplet's size predominately dictates its evaporation and movement after being expelled. The sizes of the largest droplets that would totally evaporate before falling 2 m away are determined under different conditions. The maximum horizontal distances that droplets can reach during different respiratory activities are also obtained. Our study is useful for developing effective prevention measures for controlling infectious diseases in hospitals and in the community at large.
Practical implications: Our study reveals that for respiratory exhalation flows, the sizes of the largest droplets that would totally evaporate before falling 2 m away are between 60 and 100 microm, and these expelled large droplets are carried more than 6 m away by exhaled air at a velocity of 50 m/s (sneezing), more than 2 m away at a velocity of 10 m/s (coughing) and less than 1 m away at a velocity of 1 m/s (breathing). These findings are useful for developing effective engineering control methods for infectious diseases, and also for exploring the basic transmission mechanisms of the infectious diseases. There is a need to examine the air distribution systems in hospital wards for controlling both airborne and droplet-borne transmitted diseases.
Similar articles
-
Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems.Indoor Air. 2006 Apr;16(2):111-28. doi: 10.1111/j.1600-0668.2005.00407.x. Indoor Air. 2006. PMID: 16507039
-
Some questions on dispersion of human exhaled droplets in ventilation room: answers from numerical investigation.Indoor Air. 2010 Apr;20(2):95-111. doi: 10.1111/j.1600-0668.2009.00626.x. Epub 2009 Sep 24. Indoor Air. 2010. PMID: 20002792
-
Transport characteristics of expiratory droplets and droplet nuclei in indoor environments with different ventilation airflow patterns.J Biomech Eng. 2007 Jun;129(3):341-53. doi: 10.1115/1.2720911. J Biomech Eng. 2007. PMID: 17536901
-
A review on the applied techniques of exhaled airflow and droplets characterization.Indoor Air. 2021 Jan;31(1):7-25. doi: 10.1111/ina.12770. Epub 2020 Dec 28. Indoor Air. 2021. PMID: 33206424 Free PMC article. Review.
-
Droplet fate in indoor environments, or can we prevent the spread of infection?Indoor Air. 2006 Oct;16(5):335-47. doi: 10.1111/j.1600-0668.2006.00432.x. Indoor Air. 2006. PMID: 16948710 Review.
Cited by
-
Masks and respirators for prevention of respiratory infections: a state of the science review.Clin Microbiol Rev. 2024 Jun 13;37(2):e0012423. doi: 10.1128/cmr.00124-23. Epub 2024 May 22. Clin Microbiol Rev. 2024. PMID: 38775460 Review.
-
Assessment of the potential role of atmospheric particulate pollution and airborne transmission in intensifying the first wave pandemic impact of SARS-CoV-2/COVID-19 in Northern Italy.Bull Atmos Sci Technol. 2020;1(3-4):515-550. doi: 10.1007/s42865-020-00024-3. Epub 2020 Dec 21. Bull Atmos Sci Technol. 2020. PMID: 38624634 Free PMC article.
-
Numerical performance of CO2 accumulation and droplet dispersion from a cough inside a hospital lift under different ventilation strategies.Sci Rep. 2024 Mar 21;14(1):6843. doi: 10.1038/s41598-024-57425-z. Sci Rep. 2024. PMID: 38514758 Free PMC article.
-
"Parametric study on the age of air in a full-scale office room using perforated duct diffusers.".Heliyon. 2024 Feb 23;10(5):e26667. doi: 10.1016/j.heliyon.2024.e26667. eCollection 2024 Mar 15. Heliyon. 2024. PMID: 38463864 Free PMC article.
-
Three dimensional analysis of the exhalation flow in the proximity of the mouth.Heliyon. 2024 Feb 15;10(4):e26283. doi: 10.1016/j.heliyon.2024.e26283. eCollection 2024 Feb 29. Heliyon. 2024. PMID: 38434078 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources